Precise, quick recovery of microliter volumes of concentrate from starting volumes of up to 3.5 mL

  • Fast recovery. Achieve 100x concentration and greater than 90% recovery in just minutes.
  • Available with low protein-binding Omega™ membrane.
  • Microsep device has deadstop to prevent samples from spinning to dryness.
  • Ultrasonically welded seal prevents solution bypass.
  • Versatile. Omega membrane available in a variety of MWCOs color coded for easy identification.
  • Concentrate dilute protein samples prior to electrophoresis.
  • Buffer exchange and salt removal.
  • Remove proteins and particulate from samples for HPLC analysis of drugs, amino acids, and antibodies.
  • Isolate low molecular weight compounds from fermentation broths for natural product screening.
  • Recover biomolecules from cell culture supernatants or lysates
     
     
     
    • Concentrate dilute protein samples prior to electrophoresis.
    • Buffer exchange and salt removal.
    • Remove proteins and particulate from samples for HPLC analysis of drugs, amino acids, and antibodies.
    • Isolate low molecular weight compounds from fermentation broths for natural product screening.
    • Recover biomolecules from cell culture supernatants or lysates
       
      Materials of Construction
      Filter Media: Omega membrane (low protein-binding, modified polyethersulfone on polyethylene substrate)
      Sample Reservoir and Membrane Support Base: Styrene acrylonitrile (SAN)
      Filtrate Receiver and Concentrate Cup: Polypropylene
      Cap: Polyethylene
      Effective Filtration Area
      0.46 cm2
      Dimensions
      Outside Diameter: 1.7 cm (0.7 in.)
      Overall Length (fully assembled with cap): 9.3 cm (3.6 in.)
      Minimum Tube Diameter Adapters
      1.7 cm
      Capacities
      Maximum Sample Volume: 3.5 mL
      Final Concentrate Volume: 30 - 40 µL (45° angle rotor), 40 - 50 µL (34° angle rotor)
      Filtrate Receiver Volume: 3.5 mL
      Concentrate Cup Volume: 0.5 mL
      Hold-up Volume (membrane/support): 20 µL
      Operating Temperature Range
      0 - 40 °C (32 - 104 °F)
      pH Range
      1 - 14
      Maximum Centrifugal Force
      7,500 x g
      Centrifuge
      A fixed angle rotor that accepts 17 x 100 mm tubes and is capable of 3,000 to 7,500 x g
      Sanitization
      Provided non-sterile; may be sanitized by filtering 70% ethanol through the device prior to use
       
    Part Number Description Pkg
    Microsep Centrifugal Devices with Omega Membrane
    OD001C41 1K, yellow (outside the USA order OD001C40) 24/pkg
    OD001C46 1K, yellow (outside the USA order OD001C45) 100/pkg
    OD003C41 3K, gray (outside the USA order OD003C40) 24/pkg
    OD003C46 3K, gray (outside the USA order OD003C45) 100/pkg
    OD010C41 10K, blue (outside the USA order OD010C40) 24/pkg
    OD010C46 10K, blue (outside the USA order OD010C45) 100/pkg
    OD030C41 30K, red (outside the USA order OD030C40) 24/pkg
    OD030C46 30K, red (outside the USA order OD030C45) 100/pkg
    OD050C41 50K, green (outside the USA order OD050C40) 24/pkg
    OD050C46 50K, green (outside the USA order OD050C45) 100/pkg
    OD100C41 100K, clear (outside the USA order OD100C40) 24/pkg
    OD100C46 100K, clear (outside the USA order OD100C45) 100/pkg
    OD300C41 300K, orange (outside the USA order OD300C40) 24/pkg
    OD300C46 300K, orange (outside the USA order OD300C45) 100/pkg
    OD990C41 1000K, purple (outside the USA order OD990C40) 24/pkg
    OD990C46 1000K, purple (outside the USA order OD990C45) 100/pkg